NANO X1 Specifications & Configuration SheetGenerated on 11/04/2026
- Organization
- Customer type
- Contact number
NANO X1
Microvolume Spectrophotometer
For nucleic acid, protein and routine UV-VIS measurements

ModelNANO X1
Fluorescence module✕
Cuvette module✕
Built-in battery✕
Receipt printer✕
Memory & storage2G + 16G
Measurement capabilities
- Nucleic acid concentration
- ✓
- Protein concentration
- ✓
- UV-VIS
- ✓
- Fluorescence detection
- -
- Kinetics analysis
- -
- OD600
- -
Modules & options
- Vortex mixing
- Standard
- Fluorescence excitation channels (choose two of four)
- Not applicable
- Receipt printer
- None
- EvolCare+ service
- Not selected
Standard delivery contents
| Item | Quantity | Notes |
|---|---|---|
| NANO X1 instrument | 1 unit | |
| Power adapter and power cord | 1 set | 12 V DC external adapter |
| User manual | 1 copy | |
| Calibration certificate | 1 copy | Factory calibration |
NANO X1 Specifications & Configuration SheetGenerated on 11/04/2026
Specifications
Instrument measurement performance
- Effective wavelength range
- 190–1000 nm
- Minimum sample volume
- Routine minimum: 1 µL
- Recommended sample volume
- 2 µL
- Measurement time
- Approx. 6–10 seconds
- dsDNA concentration range
- 2.0–37,500 ng/µL
- Protein (BSA) concentration range
- 0.06–1,125 mg/mL
- Path length
- 1–0.02 mm
- Absorbance range
- 0.04–550 A (10 mm equivalent)
- Absorbance precision
- 0.002 AU or 1%, whichever is greater
- Absorbance accuracy
- 1.5% (260 nm, 0.75 AU)
EVO RAY spectrometer
- Optical design
- Reflective Czerny–Turner
- Detector
- 2048-pixel linear CCD array
- A/D conversion
- 16 bit
- Spectral resolution
- ≤1.5 nm FWHM
- Wavelength accuracy
- 0.5 nm
Optical path & calibration
- Light source
- Pulsed xenon flash lamp
- Optical path
- Transmission with fiber-optic light delivery
- Path-length control
- Driven by a linear stepper motor
- Factory calibration
- Reference standards traceable to the National Institute of Metrology, China
Hardware & electrical specifications
- Display
- 7-inch touchscreen
- Display resolution
- 1024 × 600
- Touch operation
- Supports operation with gloves
- Memory & storage
- 2G + 16G, 4G + 32G or 8G + 64G options
- External connections
- 2 × USB, Type-C, Ethernet port
- Wireless
- Wi-Fi, wireless hotspot
- Power supply
- 12 V DC external adapter
- Power consumption
- Typical 12 W, maximum 30 W
- Instrument weight
- 3 kg
- Sample-contact surfaces
- Quartz fiber end faces + stainless steel
- Mixing
- Top-mounted vortex mixer, standard on all models
- Enclosure
- Dark gray or white, with a glass top surface
- Nucleic acid concentration
- Protein concentration
- UV-VIS
- Fluorescence detection
- Kinetics analysis
- OD600
- Vortex mixer
- Battery module
- Wi-Fi connectivity
- Email sending
- Wireless screen mirroring
- Audit trail